Beranda » Kanomax » Particle Counter » Laser Particle Sensor with Built-In Pump – Model 3720-06

Laser Particle Sensor with Built-In Pump – Model 3720-06

Laser Particle Sensor with Built-In Pump – Model 3720-062-channel laser particle sensor for facility monitoring applications.

The Kanomax Laser Particle Sensor – Model 3720-06 with Built-In Pump is designed to fit into your existing monitoring system, or it can be used as a standalone unit to monitor a critical area when connected to an alarm or controller.

It is available with 1.0 CFM (28.3LPM) flow rate. Order a unit with up to 4 channels in the following ranges: 0.3, 0.5, 0.7, 1.0, 3.0, 5.0, and 10 micrometers.

Laser Particle Sensor with Built-In Pump – Model 3720-06

2-channel laser particle sensor for facility monitoring applications.

The Kanomax Laser Particle Sensor – Model 3720-06 with Built-In Pump is designed to fit into your existing monitoring system, or it can be used as a standalone unit to monitor a critical area when connected to an alarm or controller.

It is available with 1.0 CFM (28.3LPM) flow rate. Order a unit with up to 4 channels in the following ranges: 0.3, 0.5, 0.7, 1.0, 3.0, 5.0, and 10 micrometers.

Features of Laser Particle Sensor 3720-06

  • Select 2ch or 4ch from the following: (0.3, 0.5, 0.7, 1.0, 3.0, 5.0, 10.0 µm)
  • Built-in pump with exhaust HEPA filter
  • Fully compliant with ISO 21501-4 and JIS B9921
  • Separate pump section for easy maintenance
  • Communication: Ethernet, RS485 & Analog Output
  • Data storage: Max. 5000 data
  • Power supply: DC15-28 V, AC 100 – 240 V, PoE++

Applications of Laser Particle Sensor 3720-06

  • Facility Particle Monitoring
  • Hospital Surgical Room
  • Cleanroom Monitoring
  • Building Monitoring System

Specifications of Laser Particle Sensor 3720-06

Specifications
Model
3270-06
Particle Sizes

① 0.5 and 5.0 µm (standard setting)
② Selectable 2 or 4ch from 7 particle sizes
0.3, 0.5, 0.7, 3.0, 5.0, 10.0 µm (selectable setting)

Laju Aliran
28.3 L/min (1 CFM)
Optical Source
Laser Diode
Efisiensi Counting
Compliant with ISO 21501-4, JIS B9921
Batas Konsentrasi
1.000.000 CNT/ft3
Pompa
Built-in Pump
Interface
RS485
Komunikasi
Ethernet, RS 485, Analog Output (4-20 mA)
Penyimpanan Data
Max 5.000 data
Sumber Daya listrik

① DC Power supply: DC 15 to 28 V 2.0 A
② AC Adapter: AC 100 to 240 V (50/60 Hz) DC 24 V 2.1A
③ PoE Switch Power Supply 802.3 bt (PoE++)

Dimensions & Weight
180 W x 110 D x 190 H mm/ Approx. 3.4 kg
Storage Environment
10 to 50℃, 95%RH or less (*no condensation)
Operational Environment
10 to 30℃, 20 to 85%RH (*no condensation)
Desain Laser Particle Sensor Model 3720-06

Standard Accessories of Laser Particle Sensor 3720-06

  • Instruction Manual,
  • AC Adapter,
  • Zero Filter
Zero Filter Laser Particle Sensor Model 3720-06

Optional Accessories of Laser Particle Sensor 3720-06

  • USB-RS485 converter,
  • RS232C-RS485 converter,
  • Isokinetic probe,
  • Pump unit,
  • IP65 protective case

Posting Serupa