Home » Ametek-Mocon (Dansensor) » Gas Mixer » MAP Mix Provectus Argon – Gas Mixer for Mixing 2 or 3 Gasses

MAP Mix Provectus Argon – Gas Mixer for Mixing 2 or 3 Gasses

gas-mixer-campur-map-mix-provectus-argonGas mixer for mixing 2 or 3 gasses: argon, carbon dioxide, nitrogen, oxygen and air.

A new smart way of mixing MAP gas in your Modified Atmosphere Packaging production.

  • Innovative touchscreen, which is easy to set up and use
  • Enhanced traceability options
  • Low risk of operator errors
gas-mixer-campur-map-mix-provectus-argon

Gas mixer for mixing 2 or 3 gasses: argon, carbon dioxide, nitrogen, oxygen and air.

A new smart way of mixing MAP gas in your Modified Atmosphere Packaging production.

  • Innovative touchscreen, which is easy to set up and use
  • Enhanced traceability options
  • Low risk of operator errors

Overview​

The revolutionary Dansensor ® MAP Mix Provectus Argon uses an entirely new operating principle to advance the accuracy, operation and appearance of a gas mixer. Simple to use, highly reliable and rich in data, this mixer gives vital feedback on information such as current gas flow, total gas consumption and actual gas mix at any time.

It is also simple to configure. When ordering, you no longer need to worry about specifying the correct pressure, combinaion of gasses or whether it will work with your onsite generation system. Your only decision is whether you need to mix two or three gasses. All other specifications can be set the first time you start the gas mixer.

Even though it is only slightly larger than a shoebox, the Dansensor MAP Mix Provectus Argon still delivers an outstanding gas mixing capacity of up to 90 m3/hour (3200 SCHF). If you require even more, you can bridge up to three mixers and triple the capacity.

Additional benefits with the Dansensor MAP Mix Provectus:

  • Full integration with Dansensor® MAP Check 3
  • Options for mixing 2-3 gases, including O2, N2, CO2, and Ar
  • Data logging of gas consumption, date, time and gas mix

Features​ and Benefits​

Benefits
  • Uses an intuitive touch screen for easy set-up and operation
  • Meets traceability requirements by storing accurate information about current gas flow, consumption over time and gas mix
  • Avoids operator errors with programming of up to 10 standard gas mixes
  • Integrates fully with the Dansensor MAP Check 3 gas analyzer for ultimate effectiveness
  • Helps reduce gas cost on flow packaging machines when used in combination with Dansensor MAP Check 3
gas-mixer-argon
Features
  • Data logging of consumption, date, time and gas mix
  • Very low pressure drop over the mixer, making it suitable for working with nitrogen and oxygen generators
  • USB, Ethernet (LAN), RS232, Modbus TCP connections for data logging and control
  • Mixes oxygen, nitrogen, carbon dioxide, air and argon
MAPcheck3-backside

Technical Specifications

General standard features
Mixer configurations
2-gas or 3-gas models available, with LCD display or as “Black-Box” without display
Connections
2 x RS232C, LAN 10/100 Mbit (Modbus TCP), USB, 24 VDC logic for start/stop and alarm
Power supply
103-132 / 207-264 VAC (autoranging), 47-63 Hz. 24 VDC
Dimensions
192 x 230 x 375 mm (H x W x D)
Weight
12.0 - 14.0 kg
Parameter Mixer
Gas media
Any mix of dry O2, CO2, N2 , air or Ar (0°C to +50°C gas temperature)
Gas inlet pressure
2 to 10 bar
Pressure drop
Example: 1 bar at 10 bar input pressure
Gas flow per gas string
6 to 500 L/min
Output gas flow
Total output flow up to: 1000 L/min (2-gas) and 1500 L/min (3-gas) depending on mixture setting
Mixer settings
Range 0%, 2% - 100%
Mixer accuracy
± 2% absolute in flow ranges above 50 L/min total output flow
Flow measuring
Total and daily consumption
Operating modes
Buffer or flow configuration, selectable in software and by installation
Mix 2-gas 3-gas
Typical mix 1:
Ar 82% + CO2 18%, flow range: 33 to 609 L/min
Ar 70% + CO2 20% + O2 10%, flow range: 60 to 714 L/min
Typical mix 2:
Ar 90% + CO2 10%, flow range: 60 to 555 L/min
Ar 70% + CO2 28% + O2 2%, flow range: 300 to 714 L/min
Worst case mix:
Ar 98% + CO2 2%, flow range: 300 to 509 L/min
Ar 88% + CO2 10% + O2 2%, flow range: 300 to 568 L/min
Best case mix:
Ar 50% + CO2 50%, flow range: 12 to 1000 L/min
Ar 34% + CO2 33% + O2 33%, flow range: 18 to 1470 L/min

Optional

MAPcheck3-IP45
IP 45 - accessory kit for improved dust & water protection
buffer-tank
Buffer Tank

Video Information​

More Information

Get more information and English brochure for this Automatic Gas Mixer here!