Home » Bellingham + Stanley » Polarimeter » ADP 600 Polarimeters – Single/Dual/Multiple Wavelength Polarimeter Series with Temperature Control

ADP 600 Polarimeters – Single/Dual/Multiple Wavelength Polarimeter Series with Temperature Control

ADP 600 Polarimeters Multi Wavelength Polarimeter

Digital Polarimeters with Temperature Control

Bellingham + Stanley Single/Dual/Multiple Wavelength Polarimeter ADP600 Series with temperature control are designed for measuring optical rotation.

They are especially suited for use by scientists wishing to measure chiral compounds and other optically active substances in the chemical, pharmaceutical and food sectors as well as for use in academic research.

The ADP600 Series of polarimeters are available as multiple, dual, or single wavelength models, and with the ability to measure optical rotation to 4 decimal places across the visible spectrum as well as in the highly sensitive ultra-violet region. The series is split between 325, 365, 405, 436, 546, 589 & 633nm wavelengths depending on the model. Other wavelengths available on request, subject to interference filter availability.

The line of digital polarimeters features Xylem’s XPC temperature control technology. XPC technology replaces air temperature systems seen in previous models, providing for faster temperature stabilisation that is more representative of the sample than the air surrounding it.

The wide range of measuring capabilities, excellent temperature stability and high precision makes the ADP600 Series an excellent choice for laboratories within chemical, pharmaceutical and food sectors.

ADP600 Series Polarimeters accept standard size (30mm collar) XPC or special low volume leur taper polarimeter tubes facilitating measurement across optical path lengths between 5 and 200mm with tube diameters from 5 to 8mm being readable. Optional lids may be easily fitted to the ADP600 Series Polarimeters, facilitating sample tube entry and exit.

ADP 600 Polarimeters Multi Wavelength Polarimeter
Digital Polarimeters with Temperature Control

Bellingham + Stanley Single/Dual/Multiple Wavelength Polarimeter ADP600 Series with temperature control are designed for measuring optical rotation.

They are especially suited for use by scientists wishing to measure chiral compounds and other optically active substances in the chemical, pharmaceutical and food sectors as well as for use in academic research.

The ADP600 Series of polarimeters are available as multiple, dual, or single wavelength models, and with the ability to measure optical rotation to 4 decimal places across the visible spectrum as well as in the highly sensitive ultra-violet region. The series is split between 325, 365, 405, 436, 546, 589 & 633nm wavelengths depending on the model. Other wavelengths available on request, subject to interference filter availability.

The line of digital polarimeters features Xylem’s XPC temperature control technology. XPC technology replaces air temperature systems seen in previous models, providing for faster temperature stabilisation that is more representative of the sample than the air surrounding it.

The wide range of measuring capabilities, excellent temperature stability and high precision makes the ADP600 Series an excellent choice for laboratories within chemical, pharmaceutical and food sectors.

ADP600 Series Polarimeters accept standard size (30mm collar) XPC or special low volume leur taper polarimeter tubes facilitating measurement across optical path lengths between 5 and 200mm with tube diameters from 5 to 8mm being readable. Optional lids may be easily fitted to the ADP600 Series Polarimeters, facilitating sample tube entry and exit.

Polarimeters in line with Pharmacopoeia

The ADP600 Series Polarimeters have two pre-set operating temperatures being 20 and 25 °C in accordance with European and United States Pharmacopoeia respectively and other user temperatures between 20 and 30°C may be configured via the instrument user interface.

Peltier technology is intelligently applied to the sample tube of the new polarimeters so that measurement can be accurately made without the need of an external device such as a waterbath to control sample temperature.

Simple to use METHOD system

Methods and measuring of ADP600 SeriesIntegral to operational simplicity is the full colour, high definition, touchscreen graphical user interface. A menu structure featuring a METHODS system makes for one-touch calibration and instrument configuration; especially where the specific rotation of a few samples is being analysed over a wide range of concentrations, path lengths, temperatures, and wavelengths.

A “Mean Method” is also available, allowing several readings to be taken from a production batch with the mean being calculated and recorded once the experiment has been completed. The Mean Method is ideal for pharmaceutical applications where compliance with pharmacopoeia is required.

RFID user clearance is standard in the ADP600 Series Polarimeters. The radio frequency technology first appeared in ADP400 Series Polarimeters, allowing users to sign in, personalise settings and help facilitate auditability all at the tap of a small fob key.

The ADP600 Series Polarimeters feature a secure “print to PDF” function that may be configured to operate in secure environments in accordance with FDA regulation 21 CFR Part 11 and importantly, the ADP600 Series polarimeters meet all of the requirements, including wavelength directives of British, United States, European and Japanese Pharmacopoeia.

ADP600 Series polarimeters along with RFM900-T Series refractometers, and the ADP450 polarimeter offer the following key benefits for 21 CFR 11.

  • Compliance without an intermediate PC – less data security risk and lower system cost
  • Server synchronised clock to prevent data tampering
  • Electronic signatures including multi-verification (Submitter > Reviewer >> Approver)
  • XML output strings with encryption & MD5 check for easy connection to LIMS/Server
  • Full instrument configuration audit trail
  • Configurable users enforcing unique login & signature credentials as well as strict password control
  • Multi-reading PHR Method for batch measurement as per GLP/PHR
  • Print to Secure PDF with custom header (customer logo can be input)

Key Features Included as Standard The ADP600 Series

  • High accuracy polarimeters
  • Simple Methods system
  • Supports FDA regulation 21 CFR Part 11
  • US/EP/BP/JP compliant
  • External keyboard support
  • RFID security for user clearance
  • Choice of up to 7 common wavelengths
  • 3 USB ports for connectivity to LIMS/PC
  • Ethernet port for networking
  • XPC Peltier temperature controlled
  • Four decimal place resolution
  • Conforms to USP/EP/BP/JP
  • RFID user clearance
  • High-definition touchscreen
  • Print to secure PDF
  • Save over 8000 readings

Specifications of ADP 600 Series

General Specifications
Range (°A)
± 89 (-355 to +355 via Method selection)
Resolution (°A)
0.0001
Accuracy (°A)
± 0.003 (@546, 589 & 633nm) / ± 0.005 (@325, 365, 405 & 436nm)
Scales/Methods

Primary: Angular degrees (°A)
Other: I.S.S (z), Specific Rotation, Concentration (g/cm3), Purity, % Invert sucrose, % change (Inversion A-B) and Specific Rotation (concentration, moisture content, length)
Batch MEAN Method for Pharmacopoeia and GLP.

Optical Density Range
0.0 to 3.0 OD
Temperature Range
15-35°C
Temperature Control
Peltier (Xylem's patented XPC Technology)
Temperature Accuracy
± 0.2°C (0.5°C for faster response time in accordance with pharmacopeia)
Temperature Compensation
None, sugar, quartz, user defined
Temperature Set Points
20 & 25 °C (variable between 20-30 °C via Method)
Reading Time
15-60 seconds @ 546/589nm and 20/20°C (instrument/sample)
Tube Types
XPC (stainless steel), Low Volume, Flow-through, PEEK (Glass)*
Tube Length
5-200mm
Tube Diameter
5-8mm
User Interface
High Definition 7.4” touch-screen colour display
Light Source
UV/Vis lamp (6V, 2A >1000hrs) and narrow band pass filter(s)
Interfaces
3 x USB (A), 1 x Ethernet, 1 x RS232
Power Supply
100-250V~, 50-60 Hz. <2A
Code Description Wavelengths(s)
37-61
ADP610 single wavelength polarimeter
589 nm
37-62
ADP620 dual wavelength polarimeter
546 & 589 nm
37-63
ADP622 dual wavelength polarimeter
365 & 589 nm
37-64
ADP640 multiple wavelength polarimeter
405,436, 546, & 589 nm
37-65
ADP650 multiple wavelength polarimeter
365, 405,436, 546, & 589 nm
37-66
ADP660 multiple wavelength polarimeter
325, 365, 405,436, 546, & 589 nm
37-67
ADP670 multiple wavelength polarimeter
325, 365, 405,436, 546, 589, 633 nm

Accessories of ADP600

Glass Polarimeter Tube, Centre fill, Plastic end caps

These tubes can accept the addition of a sample temperature probe without causing interference with the measurement light beam and so are recommended for use with ADP400 and ADP600 Series polarimeters. Available as 100 mm and 200 mm lengths

Glass Polarimeter Tube, Centre fill, Metal end caps

These tubes can accept the addition of a sample temperature probe without causing interference with the measurement light beam and so are recommended for use with ADP400 and ADP600 Series polarimeters. Available as 100 mm and 200 mm lengths

Glass Polarimeter tube, Centre cup

Available as 100 mm and 200 mm lengths. Suitable for ADP430 and polarimeters not requiring temperature control.

Metal Polarimeter tube, Two fillers, Metal end caps

These tubes can accept the addition of a sample temperature probe without causing interference with the measurement light beam and so are recommended for use with ADP450 and ADP600 Series polarimeters. Available as 100 mm and 200 mm lengths

Low Volume Metal Polarimeter tubes

Sample entry and exit is via UNF 28 female threads and PTFE pipe connectors, 1 with a Luer Swagelok® fitting for sample application using a syringe. Suitable for ADP400 Series and ADP600 Series polarimeters.

Available in :

  • 5 x 5mm with volume of 0.1 ml
  • 5 x 10 mm with volume of 0.2 ml
  • 5 x 25 mm with volume of 0.5 ml
  • 5 x 50 mm with volume of 1.0 ml
Glass Polarimeter tube, Centre cup, Metal end caps

These special XPC tubes are specifically designed for use with our ADP450 digital polarimeter incorporating XPC Technology. XPC technology provides rapid Peltier temperature control of the sample without the need for a cumbersome and costly water bath. Suitable for ADP400 Series and ADP600 Series polarimeters. Available as 100 mm and 200 mm lengths

XPC Temperature Control Adaptor for ADP450 & ADP600 Series polarimeters

Special heat transfer adaptor (heat exchanger) for use with Xylem’s XPC Technology onboard ADP450 and ADP600 Series digital polarimeters. This XPC adaptor must be used with 100 or 200mm stainless steel polarimeter tubes (available separately).

Glass Polarimeter Tube, Centre fill, PEEK end caps, for HCl

Glass Polarimeter tube with PEEK endcaps for use with highly acid samples such as Hydrochloric acid use within the pharmaceutical industry as a solvent. Spare end caps, seals as well as UV pass windows are also available as is an XPC adaptor for use in polarimeters boasting XPC Technology such as the ADP450 or ADP600-XPC Series polarimeters. The tubes are available in 100mm or 200mm tube lengths.

Glass Polarimeter tube, Bulb, Plastic end caps

Precision ground glass polarimeter tube with plastic ends and bulb to clear bubbles. Ideal for entry level use in food applications as well as academia due to their low price point. These tubes are available in 100mm or 200mm tube lengths.

Windows (cover glasses) for polarimeter tube, spare parts

Cover glass or window “seals” for polarimeter tubes. Available in:

  •  XPC – 10mm diameter
  • Standard – 15.5mm diameter
  • Low Volume – 20mm diameter
  • Flow & Jacket – 22.5mm diameter
Rubber stoppers for centre fill polarimeter tube, spare parts

Rubber stoppers for centre fill polarimeter tubes, suitable for volatile samples. Sold as a pack of 5 pieces.

End caps for polarimeter tubes, Metal, Plastic, PEEK, spare parts

Available in:

  • XPC – 10mm diameter
  • Standard – 15.5mm diameter
  • Flow – 22.5mm diameter
  • Jacket Centre – fill – xy diameter
Washers for polarimeter tube end caps, spare parts

Available in:

  • XPC – 10mm diameter
  • Standard – 15.5mm diameter
  • Low Volume – 20mm diameter
  • Flow & Jacket – 22.5mm diameter
Polarimeter, Quartz Control Plate

Quartz Control Plates (QCP) for verifying and calibrating polarimeters.

Hastelloy® Temperature Sensor, ADP Polarimeter

Hastelloy® temperature sensor for ADP400 and ADP600-XPC polarimeters used with aggressive, highly acidic samples and/or solvents that corrode stainless steel.

Interchangeable lids for ADP Polarimeters

Miniature Printer, serial, 230VAC, CBM910, Bellingham + Stanley

Ideal for RFM700, RFM300 and RFM900 digital refractometers and all ADP polarimeters

USB to RS232 printer adaptor for refractometers and polarimeters

Paper rolls (20) for CBM910 printer

Spare ribbon for CBM910 printer, black, each