Home » Ebro - Xylem Analytics » Data Logger for Validation » EBI 12 Validation Data Logger » EBI 12-T210 / T211 Temperature Data Logger for Validation in Small Container

EBI 12-T210 / T211 Temperature Data Logger for Validation in Small Container

data-logger-penetrasi-panas-suhu-produk-pasteurisasi-sterilisasi-ebi-12-T210-T211Robust data logger for regular checks in canning factory.

This data logger can be used universally. The logger is often used in the following areas for temperature measurement.

The logger is used for pasteurization control, especially in small containers.

The logger needle is inserted into the container from the outside.

The data logger is often used to check sterilization as part of quality assurance in production.

Due to its large measuring range, the data logger is often used for mapping the temperature in warehouses, refrigerators, freezers, incubators and many more.

Benefits :

  • wireless measurement
  • Versatile
  • large measuring range

Applications :

  • Food Safety
  • Pasteurization Control
  • PU value determination
  • Sterilization
  • F0 Value calculation
data-logger-penetrasi-panas-suhu-produk-pasteurisasi-sterilisasi-ebi-12-T210-T211

Robust data logger for regular checks in canning factory.

This data logger can be used universally. The logger is often used in the following areas for temperature measurement.

The logger is used for pasteurization control, especially in small containers.

The logger needle is inserted into the container from the outside.

The data logger is often used to check sterilization as part of quality assurance in production.

Due to its large measuring range, the data logger is often used for mapping the temperature in warehouses, refrigerators, freezers, incubators and many more.

Benefits :

  • wireless measurement
  • Versatile
  • large measuring range

Applications :

  • Food Safety
  • Pasteurization Control
  • PU value determination
  • Sterilization
  • F0 Value calculation

Technical Data of EBI 12-T210 / T211

Specification Information

Data memory

27,840 measurement values

Sensor

Pt 1000, class A

Weight

approx. 110 g

Accuracy

± 0,5 °C (-55 °C ... -40 °C)
± 0,2 °C (-40 °C … 0 °C)
± 0,1 °C (0 °C … +150 °C)

Protection class

IP68

Dimensions

(Ø x H) 48 mm x 24 mm - Needle length 50 mm (T210)
(Ø x H) 48 mm x 24 mm - Needle length 75 mm (T211)

Resolution

0,01 °C

Certificate

Factory Calibration: -20 °C, 0 °C, +60 °C and +134 °C

Measured variables

Temperature

Interval

1 s ... 24 h

Battery

Lithium battery (3,6 V), user replaceable

Measuring range

-55 °C … +150 °C

Storage temperature

-20 °C ... +70 °C

Software / Interface

Winlog.pro Software

  • Enables real-time monitoring with wireless data loggers
  • Formula editor for calculating the F0-value of the absolute humidity,
    the PE value etc.
  • Display oft the timeline either absolute or relative
  • Customized definition of individual areas possible (with their
    own statistics and calculations)
  • Including calibration tool for data loggers
  • Integration of pictures and graphics into reports possible
  • IQ/OQ documentation to qualify the system is available

Winlog.validation Software for routine control and validation

Save time and effort for the regularly required process validation with the help of the powerful reporting and evaluation software Winlog.validation.

The automatic recognition of the individual process steps makes your work easier and meets the high demands of validation and qualification in pharmacy and medicine.

The TÜV-certified evaluation software Winlog.validation enables you to carry out automatic and manual evaluations of the processes. You can adapt it to your needs at any time with individual process parameters and test criteria.

  • TÜV certified
  • User-friendly – DIN EN ISO 9241-110:2008 conform
  • Central user administration in local area network possible
  • Automatic report generation
  • Automatic user-defined calculations
  • Automatic identification of process cycles
  • Creation of user-defined masters for specific devices and
    thermal processes
  • Three-dimensional demonstration of sensor placement or placement of
    the sensors directly on an application image possible
  • FDA 21 CFR Part 11
  • DIN ISO/IEC 25051:2014
  • Incl. IQ- / OQ-Documentation for software Qualification
  • Automatic evaluation of validation processes

 

Interface Set SI 1300

  • USB-connector
  • Colored LED signals programming,
    readout and faulty execution
  • Including Antenna AL 111
  • Software Winlog.pro

Interface Set SI 1100

  • USB-connector
  • Colored LED signals programming,
    readout and faulty execution
  • Software Winlog.pro

Accessories

EBI NI-140 Nipple
EBI NI-140 Nipple - Nipple 140°C for EBI 10-T230, 231,232,233 and EBI 100-T230, 231, 232, 233 logger For positioning the logger exactly in bottles or cans.
ebi-kv3-clamp-connection
EBI-KV3 Clamp Connection - With this clamp connection, the data logger can be attached to loggers and jars.
EBI-DA-Set
EBI-DA-Set - This adapter set provides elements for mechanically attaching the data logger to cans or plastic pouches. Suitable for data loggers of the EBI-series with axial, radial or external sensor.

Video Information​

More Information

Get more information and English manual for this Temperature Data Logger here!