Home » Systec » Autoclave » H Series – Double Door (Pass Through) Autoclaves

H Series – Double Door (Pass Through) Autoclaves

autoklaf-systec-hx-double-doorFor use under the most stringent clean room and safety conditions.

  • For biological safety laboratories. Fitting as a sterilization and pass-through lock for protecting the external environment.
  • For clean rooms in laboratories and production facilities as a sterilization and pass-through lock separating sterile and non-sterile areas.
  • Operation, however, can be carried out from both sides,
    the position (open or closed) of the opposite door being indicated on the display.

The new, improved generation of Systec H-Series autoclaves comes in a new design, with a fully revamped interior and a completely new touchscreen control.

The pressure vessel is made of corrosion-resistant stainless steel and is thus easy to clean.

Dual sensors as standard, Temperature and pressure are controlled via an electronic pressure sensor, as well as via a flexible temperature sensor in the chamber or in a reference vessel (with liquids).

autoklaf-systec-hx-double-door

For use under the most stringent clean room and safety conditions.

  • For biological safety laboratories. Fitting as a sterilization and pass-through lock for protecting the external environment.
  • For clean rooms in laboratories and production facilities as a sterilization and pass-through lock separating sterile and non-sterile areas.
  • Operation, however, can be carried out from both sides,
    the position (open or closed) of the opposite door being indicated on the display.

The new, improved generation of Systec H-Series autoclaves comes in a new design, with a fully revamped interior and a completely new touchscreen control.

The pressure vessel is made of corrosion-resistant stainless steel and is thus easy to clean.

Dual sensors as standard, Temperature and pressure are controlled via an electronic pressure sensor, as well as via a flexible temperature sensor in the chamber or in a reference vessel (with liquids).

Application

Liquids
Nutrient and culture media

sterilisasi-solid-instrumen
Solids and porous material
Instruments, pippetes, fabrics, tubing, glassware
destruksi-limbah
Waste
Destructive sterilization of liquid waste in bottles, or solid waste in destruction bags
destruksi-bio-hazard
Biological hazards Sterilization
For used in safety level laboratories
sterilisasi-kontak-lens-ampul-IV-bag
Special Program
Such as product sterilization, contact lens, ampoule, IV bag
sterilisasi-gelas-tes

Glass test Program
According ISO 4802-2, DIN 52339

Dimensions

dimensi-autoklaf-double-door-h
Serie Chamber Dimension
Ø x depth (mm)
Chamber Volume
in liters total / nominal
Systec HX-90 2D
400 x 750
100 / 90
Systec HX-150 2D
500 x 750
160 / 150
Systec HX-200 2D
500 x 1000
210 / 200
Systec HX-320 2D
740 x 750
370 / 320
Systec HX-430 2D
740 x 1000
480 / 430
Systec HX-540 2D
740 x 1250
590 / 540
Systec HX-650 2D
740 x 1500
700 / 650
Systec HX-580 2D
1000 x 750
680 / 580
Systec HX-780 2D
1000 x 1000
880 / 780
Systec HX-980 2D
1000 x 1250
1075 / 980
Systec HX-1180 2D
1000 x 1500
1270 / 1180
Systec HX-1380 2D
1000 x 1750
1465 / 1380
Systec HX-1580 2D
1000 x 2000
1665 / 1580

Design

Standard Features

Feature HX

Integrated, separate steam generator

Yes

Housing, support frame and pressure vessel made of corrosion-resistant stainless steel

stainles-steel-316-chamber-h-serie

Yes

Temperature and pressure range, 140 °C and 4 bar absolute pressure

Yes

The pressure vessel of the autoclave is made of corrosion-resistant stainless steel 1.4404 (AISI 316L)

Yes

All connections on the pressure vessel are designed as Tri-Clamp

tri-clamp

Yes

All fittings and valves in the supply lines (from media connection to sterilization chamber) for demineralized water, steam or compressed air are made of stainless steel.

All piping is made of FDA-certified PTFE

Yes

Touch screen control

v-serie-display-touch-screen-2

Yes

Number of sterilization programs (up to 100)

Yes

Code-secured access rights for changing parameters and further safety-relevant intervention

Yes

Internal memory capacity for storing up to 10 years of data backups

Yes

Timer for programmable start time

Yes

Flexible PT-100 temperature sensor (class A)

flexible-temperature-sensor-d-serie

Yes

Additional temperature sensor in condensate exhaust

condense-temperature-sensor

Yes

Special program for Durham tubes

Yes

Calculation of F0 value

Yes

Special program for destructive sterilization with fractional heating for more efficient venting

pulsed heat-up

Yes

Waste water temperature is water-cooled and thermostatically controlled (Default setting : 70 °C)

exhaust-temperature-sensor-d-seriejpg

Yes

Adjustable automatic opening of door at end of program

Yes

Network and USB ports for external data transfer

Yes

Text input for batch information (up to 20 characters)

text-input

Yes

User account control (standard).

The standard user account control has three permanently pre-configured and fixed user groups, each with one available user (Administrator, Operator or Supervisor).

Yes

Validation port for introducing measuring equipment

validation-port

Yes

Integrated feature for comprehensive batch documentation, with export as PDF and CSV

export-pdf-csv

Yes

Time synchronization with time server via network or internet

Yes

Optional & Accesories

Mantle cooling with cooling water and support pressure
Radial Ventilator
ultra-cooler-h-serie-autoklaf
Ultra Cooler
vacuum-system-D-serie-autoklaf
Vacuum System
Superdry
exhaust-filter-h-serie-autoklaf
Exhaust Air Filtration
printer-autoklaf
Printer
Stainless steel wire mesh baskets, stackable
Loading Shelves for sterilizing small items
transport-loading-troley-h-serie
Transport cart and transfer cart with Easy Load
stainles-steel-316-casing-h-serie
Stainless Steel Casing
save-to-folder
Save to folder
scada-connection
SCADA connection
fda-21-cfr-part-11-autoklaf-h-serie
Advanced CFR Part 11 solution

Video Information​

More Information

Get more information and English brochure for this Systec Autoclave here!

Share this information :