Home » Ebro - Xylem Analytics » Data Loggers for Monitoring » EBI 310 Multi-Use PDF Data Logger High Precision » EBI 310 TH – Multi-Use PDF Data Logger with External Humidity and Temperature Probe

EBI 310 TH – Multi-Use PDF Data Logger with External Humidity and Temperature Probe

data-logger-pemantauan-suhu-kelembaban-ruang-transportasi-ebi-310-thTemperature & Relative humidity Data Logger high precision version for transport and storage monitoring.

Applications : Logistics, Laboratory, Pharma – Vaccine –Drugs, Food and Storage control.

  • Tamper proof
  • Easy use through automatic PDF report generation, direct USB readout and configuration
  • Minimize training costs and user errors through simple,
    easy to use design
  • Eliminate costly and time consuming IQ/OQ procedures through standard reporting process
  • Reduce IT costs with due to the standardized software
data-logger-pemantauan-suhu-kelembaban-ruang-transportasi-ebi-310-th

Temperature & Relative humidity Data Logger high precision version for transport and storage monitoring.

Applications : Logistics, Laboratory, Pharma – Vaccine –Drugs, Food and Storage control.

  • Tamper proof
  • Easy use through automatic PDF report generation, direct USB readout and configuration
  • Minimize training costs and user errors through simple,
    easy to use design
  • Eliminate costly and time consuming IQ/OQ procedures through standard reporting process
  • Reduce IT costs with due to the standardized software

EBI 310 TH - USB Data Logger for Cold Chain Monitoring

The easy to use data loggers with USB connection monitor the temperature during transport and storage of sensitive goods like medicine, food, serums etc.

Measurement reports are created automatically as PDF files when you connect the logger to a PC.

ebi-310-th-data-logger

Program | Measure

  • Programming of the logger with the help of the free online configurator at www.ebi300.com or optional via the software Winlog.basic or Winlog.pro
  • Set optional limits and start to record the measurement data
EBI 300 programming & measure

Connect | Readout

  • Connection of the logger to any PC via the USB port
  • Automatic generation of a PDF report with all important measurement data
EBI 300 connection

Evaluate | Archive

  • Store, save or email the PDF report
  • Further processing of the measurement data with the software Winlog.basic or Winlog.pro
EBI 300 pdf data

Technical Data of EBI 310 TH

Specification Information

Data memory

120,000 measurement

Sensor

PT 1000

Weight

approx. 35 g

Accuracy

(intern)
± 0,2 °C (- 30 °C … + 30 °C),
± 0,5 °C for the remaining measuring range

(extern)
± 0,5 °C (0 °C … + 60 °C),
± 0,8 °C for the remaining measuring range

Probe
± 2% in between 10% RH … 90% RH (at 25 °C)
± 4% for the remaining measuring range

Protection class

IP20

Dimensions

129 x 33 x 14 mm

Resolution

0.1 °C

Certificate

Factory calibration certificate

Measured variables

Temperature, humidity

Interval

1 sec... 24 h

Battery

Lithium button cell (CR 2450), 3 V

Measuring range

-30 °C...+75 °C
Probe : 0% RH...100% RH

Storage temperature

-40 °C ... +85 °C

Software / Interface

Winlog.pro Software

  • Enables real-time monitoring with wireless data loggers
  • Formula editor for calculating the F0-value of the absolute humidity,
    the PE value etc.
  • Display oft the timeline either absolute or relative
  • Customized definition of individual areas possible (with their
    own statistics and calculations)
  • Including calibration tool for data loggers
  • Integration of pictures and graphics into reports possible
  • IQ/OQ documentation to qualify the system is available

Winlog.basic Software (Free)

The new free software for programming and evaluation of data loggers.

  • User friendly: intuitive and easy to use
  • Graphical and numerical display of measurement data
  • Protocol print (with printer and computers)
  • Scan and enlarge of the measurement data
  • Data export to Microsoft® Excel and PDF
  • 21 CFR Part 11 – functionality as an option

Accessories

EBI 300/310 WM2 - Wall Mount
EBI 300/310 WM2 - Wall Mount, High strength polycarbonate
EBI 300/310 WM3 - Wall Mount
EBI 300/310 WM3 - Wall Mount Stainless steel
EBI 300 - AH 300 Sinter-Filter
AH 300 Sinter-Filter (stainless steel) - The stainless steel sintered filter AH 300 also increases the protection class to IP 40. The stainless steel massively increases the mechanical protection, e.g. from crushing the filter. Nothing will happen to your probe! In addition, the stainless steel is highly resistant to corrosion even in high temperature applications.
EBI 300 - AH 100 PTFE Filter
AH 100 PTFE-Filter - The PTFE-filter AH 100 provides little protection from mechanical strain but seals the probe from dust – protection class IP 60. In dusty environments, unprotected humidity probes, or probes protected by sintered fi lters, can quickly be covered by dust. This massively affects the humidity measurement, or prohibits it entirely. It won´t happen with the PTFE filter.
ebi-310-th-tph500-probe
TPH 500 - External capacitive humidity probe

Video Information​

More Information

Get more information and English manual for this Temperature Data Logger here!

Share this information :

Similar Posts