Home » Berner » Cytotoxic / Bio-safety cabinet (BSC) » Safety Cabinet for Standard Use – Claire® pure

Safety Cabinet for Standard Use – Claire® pure

claire-pure-bio-cyto-toxic-safety-cabinetClaire® pure provides the highest quality technology at an attractive price.

LED illumination in the work area, high-performance EC fans and the touch display with intuitive menu navigation form the technical basis for the highest functionality.

This is complemented by a targeted range of options for all major applications.

Outstanding energy efficiency and low procurement and operating costs make claire® pure the ultimate in efficiency.

claire-pure-bio-cyto-toxic-safety-cabinet

Claire® pure provides the highest quality technology at an attractive price.

LED illumination in the work area, high-performance EC fans and the touch display with intuitive menu navigation form the technical basis for the highest functionality.

This is complemented by a targeted range of options for all major applications.

Outstanding energy efficiency and low procurement and operating costs make claire® pure the ultimate in efficiency.

The Power of Innovation in Biological / Cytotoxic Safety Cabinet

protection-shield

Protection Shield

The multiple award-winning “Shield Design” testifies high quality design, which combines by way of example innovation with form and function.

touch-display

Touch Display

Intuitive operation and user-friendly menu navigation.

innovative-led-technology

LED light technology

Light and even illumination of the working area thanks to high quality and dimmable LED technology.

High level of performance

High level of performance

Outstanding protection functions with relatively low flow conditions characterise this design.

Two operating points “ECO” & “GMP” are TÜV tested and certified using the microbiological test method according to DIN EN 12469, DIN 12980 and NSF 49.

High flexibility with maximum safety.

ergonomic

Ergonomics

Particularly quiet, bright operating conditions, individually adjustable work surface height and optimum legroom even for 3-filter cabinets due to the particularly compact design of the first main filter.

greentec

GreenTec

Innovative technology reduces the operating costs by up to 84%.

economical

Economical

The excellent price, the highest energy efficiency and lowest operating costs make Claire pure to Berner’s most economical safety cabinet.

Filter Technology

Filter technology

New HEPA cartridge filters for even lower sound levels and energy consumption.

Proven protection

The design of the workspace, the work aperture, the HEPA cartridge filter and the front intake ensure a very high level of protection.

2 or 3 Filter System Biological / Cytotoxic Safety Cabinet

1.

blower safety cabinet

Fluid mechanics

Air distribution, cross-sections and filters have
been optimised resulting in the lowest possible flow resistance in order to achieve a more efficient air-flow. This reduces the load on the fans which saves
valuable energy.

Top quality components

Premium quality components like EC-fans, LED lighting technology and a LED touch display reduce the active energy consumption enormously

2.

ecomode safety cabinet

Eco Mode

Intelligent control and monitoring technology reduces all consumers with one touch to a minimum.

3.

catridge filter bio safety cabinet

New HEPA cartridge filters

Improved operating characteristics significantly reduce energy consumption and sound level thanks to new suction nozzle and air distribution. Resulting longer service life of filters saves additional costs

Best Design of Biological / Cytotoxic Safety Cabinet

airflow safety cabinet

Filters are the most safety relevant components in safety cabinets. They make up the most important barrier for people, the environment and the product.

As part of a research project we were able to fluid mechanically optimize the HEPA-cartridge filters used in the 3-filter systems. Thanks to a newly designed intake port and air ducts the operating properties have been improved. Noise level and energy consumption have been reduced. The filter life has been optimised.


Proven properties have remained the same :

  • Small size and compact design
  • Maximum legroom in 3-filter-systems
  • 50% reduced changing and test expenditure compared to traditional filter systems
  • Possibility of a low contamination filter change in accordance to DIN 12980:2016
  • Fit into many standard waste disposal containers or autoclaves

The extremely low total height of 2097 mm favours the operation of an exhaust air system or exhaust cooler and allows for easy testing of the exhaust filter.

Worktop height of 770 mm, maximum legroom and a comfortable arm position.

user friendly safety cabinet

The touch display is the central interface and control unit for the user. The touch display of the new generation is intuitive in its operation with a self-explanatory menu. Premium quality pictograms and a puristic design speak a clear language.

The superior TFT-display with LED background lighting is arranged in a central position and within easy reach. The display can be easily read from a sitting as well as a standing position.

All safety-related parameters such as airflow velocities and front screen position are displayed as large graphical images. Errors are shown clearly, and potential corrective actions are suggested.

The distinguishing feature of the touch display of the new generation of safety cabinets is the intuitive operation and extremely user-friendly menu navigation- it’s easy!

Model of Biological / Cytotoxic Safety Cabinet Claire Pure

claire pure safety cabinet

2 Filter System

Biological Safety Cabinet

  • Claire pure B-2-130
  • Claire pure B-2-160
  • Claire pure B-2-190

 

3 Filter System

Biological Safety Cabinet

  • Claire pure B-3-130
  • Claire pure B-3-160
  • Claire pure B-3-190

Cytotoxic Cabinet

  • Claire pure C-3-130
  • Claire pure C-3-160
  • Claire pure C-3-190

Technical Data of Biological / Cytotoxic Safety Cabinet Claire Pure

General data

Device

Laboratory device

Type of device

Cytostatic safety cabinet or biological safety cabinet

Type of construction

DIN 12980; DIN EN 12469; NSF 49

Marking

CE

Quality management system

DIN EN ISO 9001:2008
General technical data

Nominal illuminance

0-1.100 lux

Vibration (RMS) on worktops

≤ 5μm

Sound pressure level to ISO 11201

49 to 59 dB(A)
Depending on operating mode and model size

Material specific data

Material workspace

1.5 mm stainless steel „V2A“, material no.: 1.4301

Surface finish work space

320 grit fine finish, mean roughness index Ra ≈ 1.6 μm

Material casing

Powder-coated 1.5 mm Zincor steel sheet, material no.: 1.0330

Front-, side and back panel

Multi-layer safety glass with UV-light absorbing interlayer
Electrical data

Rated voltage/ Rated frequency

230 V AC / 50/60 Hz

Power consumption

85 – ca. 550 W
Depending on operating mode and model size

Mechanical data

Width, outer

1352, 1654 and 1957 mm

Height

2097 mm

Depth

815 mm

Installation dimension

2009 x 815 mm

Worktop height

770 mm
Ventilation data

Flow rate of exhaust or inflow air

330 – 490 m³/h
Depending on operating mode and model size

Flow rate of exhaust air (with feedback-free duct connection)

450 – 600 ± 50 m³/h
Depending on operating mode and model size

Filter classes (with main, recirculation & exhaust filter)

Min. H 14 (Filtration rate: E ≥ 99,995%), gem. DIN EN 1822-1
Integral degree of filtration as minimum filtration efficiency for max. penetration,
with particles of the Most Penetrating Particle Size (MPPS)

Cleanroom class in workspace

EG-GMP-Guidelines: A; DIN EN ISO 14644-1: ISO-Class 5

Optional & Accesories

Various interfaces and additional power sockets

Interfaces allow to connect different kinds of devices within the safety cabinet. Therefore, type and quantity of the interfaces are different according to the need. Find some of the interfaces of our assortment here.


Interfaces :

  • RS 232 -> Important data (for example, from a balance, keyboard, etc.) can be send with the integrated RS-232 Data Link from the working space to the data processing system.
  • USB/USB 3.0 -> Integrated universal interface for connecting peripheral devices such as keyboard, printer, balance, etc. outside of the working space and laterally disposed of the safety cabinet with your data processing system. Mechanically stable and simple plug-in connection with fast data transfer rate. Gross data transfer rate USB 3.0: 500 mb/s
  • CAT 5 -> Integrated interface for signal transmission with high data transfer rates. It enables the exchange of data between a local area network (LAN) connected devices (computers, printers, etc.).
  • PS/2 -> Serial interface for input devices such as Keyboard and mouse.
  • 8 P -> Push/Pull Interface realised from working space to the roof (Roxtec). 8P push-pull -> circular connector connections. For Claire safety cabinets, for example, for connecting compounders or other
  • Ethernet -> Integrated dual interface for signal transmission with high data transfer rates. It enables the exchange of data between connected devices (computers, printers, etc.)in a local area network (LAN).

Powerful systems for UV-C disinfection

The built-in UV C sterilisation system disinfects with a large disinfection effectiveness the workspace thanks to its high performance and shadowfree irradiation. A high irradiance at a wavelength of 254 nm ensures a rapid killing of microorganisms (for example, about 220μW / cm² according to the manufacturer of UV lamps for models with a width of 190 cm).

From this theoretical LD90 values (kill rate: 90%) yield of vegetative bacterial cells and yeast of <2 minutes, bacterial spores (Bacillus subtilis) <5 minutes DNA and RNA viruses gen gen <3 minutes, mushrooms <10 minutes. Few specific exemptions of certain viruses and fungal spores require higher exposure times, so as Aspergillus Niger (spores) about 25 minutes and specific HIV Virus (H9) 40 min.

The appropriate exposure time can be set via the timer on the centrally located touch screen.

Low vibration weighing worktops

Achieved as a mass-spring system the work plate for micro balances provides a very stable, low-vibration area integrated into the safety cabinet. For undisturbed exact weighing or for other vibration sensitive analytical instruments.

The weighing top has a size of 313 x 600 mm and is made from 1,5 mm thick stainless steel.

The vibration (RMS) could be significantly reduced with the Low-Vibration-System below 5µm (benchmark in relevant technical standards).

The low-vibration area is indicated by a balance symbol.

 

Isokinetic sampling probe for particle monitoring

Continuous particle monitoring

Determination of particle purity class in the working space of a safety cabinet – or horizontal cabinet or an isolator

  • Monitoring the particle purity class A in the working space
  • Integration of a fixed or mobile isokinetic sampling probe

Exhaust air connection Exhaust Duct Flex for connection and feedback-free operation of air exhaust systems

The exhaust air connection FlexDuct ensures feedback-free coupling of safety cabinets to an exhaust air system acc. DIN 12980 and DIN EN 12469.

Outstanding features:

  • Very low total exhaust air volume flow reduces the operating costs significantly by upto 50%
  • Especially for ceiling heights > 2,8 m
  • Ideal for use with height adjustable base frames
  • Free of negative feedback, therefore always maximum personal protection
  • Flexible placement of the safety cabinet according to the lab conditions
  • Safety dampers enable the visual control of safe operating conditions
  • Via safety flaps adjustment of optimum exhaust air volume flow without measurements is possible
  • Fast deinstallation for exhaust air filter check

Important requirements:

  • The distance of the safety cabinet to the wall needs to be at least 7 cm for the safety flaps to open correctly in case of ventilation system failure.
  • The air ventilation system needs to be designed for a total exhaust air volume flow of : 600 +/ – 50 m³/h.
  • A circular connection to the ventilation system with a diameter of 250 mm above the safety cabinet in the ceiling or wall should be in a distance of not more than 4 m.
  • The air ventilation system must monitor the set value of the volume flow. Unsafe conditions have to be indicated by visual and acoustic warning signals.

Various connections for liquid and gaseous media

Connections are possible for a wide range of gaseous and liquid media. These can be easily integrated. Laboratory fittings are ergonomic and can be integrated into the left side panel or back panel.

Some examples :

  • flammable gases
  • non-flammable gases
  • process water
  • compressed air
  • carbon dioxide, CO2
  • nitrogen
  • drinking water
  • demineralised water
  • ultrapure water

Marking, Certificate & Award

GS-mark

Test and safety mark according to the German appliance and product safety law. Testing, certification and control by the accredited test house.

TÜV NORD CERT GmbH & Co. KG
Große Bahnstraße 31
D-22525 Hamburg
Germany

CE mark

EC directive conformity mark signifies the adherence to the basic safety and health requirements of the relevant EC directive(s).

TÜV personal certification mark


The TÜV personal certification »technical qualification verification for service technicians of microbiological safety cabinets and cytostatic safety cabinets« consists of a one-week intensive training course with subsequent theoretical and practical examinations. Personal certification is attained after successful completion of the examinations together with regular proof of calibrated measuring tools.
Testing, certification and control by the accredited test house.

TÜV NORD CERT GmbH & Co. KG
Große Bahnstraße 31
D-22525 Hamburg
Germany

More Information

Get more information and English brochure for this Bio Safety Cabinet / Cytotoxic Cabinet Claire Pure here!

Share this information :

Similar Posts