EBI 12-T101 / T101-EYELET Temperature Data Logger for The Care Sector

data-logger-distribusi-panas-suhu-mesin-cuci-ebi-12-T101-T101-EYELETDisinfection protection with A0 value control.

Robust temperature data logger for regular independent routine checks in the care sector to check the A0 value in the bedpan washer and glassware washer.

Benefits :

  • Easy to fix
  • robust data logger
  • wireless measurement
  • sterilizable data logger

Applications :

  • disinfection protection
  • Routine control in care facilities
  • A0 Value calculation
data-logger-distribusi-panas-suhu-mesin-cuci-ebi-12-T101-T101-EYELET

Disinfection protection with A0 value control.

Robust temperature data logger for regular independent routine checks in the care sector to check the A0 value in the bedpan washer and glassware washer.

Benefits :

  • Easy to fix
  • robust data logger
  • wireless measurement
  • sterilizable data logger

Applications :

  • disinfection protection
  • Routine control in care facilities
  • A0 Value calculation
EBI 12-T100-EX

EBI 12-T101

EBI 12-T100-EYELET

EBI 12 T101-EYELET

Technical Data of EBI 12-T101 / T101-EYELET

Specification Information

Data memory

27,840 measurement values

Sensor

Pt 1000, class A

Weight

approx. 110 g

Accuracy

± 0,5 °C (-90 °C … -40 °C)
± 0,3 °C (-40 °C … +105 °C)

Protection class

IP68

Dimensions

(Ø x H) 48 mm x 24 mm

Resolution

0,01 °C

Certificate

Factory Calibration: -20 °C, 0 °C and +60 °C

Measured variables

Temperature

Interval

1 s ... 24 h

Battery

Lithium battery (3,6 V), user replaceable

Measuring range

-90 °C ... +105 °C

Storage temperature

-20 °C ... +70 °C

Software / Interface

Winlog.pro Software

  • Enables real-time monitoring with wireless data loggers
  • Formula editor for calculating the F0-value of the absolute humidity,
    the PE value etc.
  • Display oft the timeline either absolute or relative
  • Customized definition of individual areas possible (with their
    own statistics and calculations)
  • Including calibration tool for data loggers
  • Integration of pictures and graphics into reports possible
  • IQ/OQ documentation to qualify the system is available

Winlog.validation Software for routine control and validation

Save time and effort for the regularly required process validation with the help of the powerful reporting and evaluation software Winlog.validation.

The automatic recognition of the individual process steps makes your work easier and meets the high demands of validation and qualification in pharmacy and medicine.

The TÜV-certified evaluation software Winlog.validation enables you to carry out automatic and manual evaluations of the processes. You can adapt it to your needs at any time with individual process parameters and test criteria.

  • TÜV certified
  • User-friendly – DIN EN ISO 9241-110:2008 conform
  • Central user administration in local area network possible
  • Automatic report generation
  • Automatic user-defined calculations
  • Automatic identification of process cycles
  • Creation of user-defined masters for specific devices and
    thermal processes
  • Three-dimensional demonstration of sensor placement or placement of
    the sensors directly on an application image possible
  • FDA 21 CFR Part 11
  • DIN ISO/IEC 25051:2014
  • Incl. IQ- / OQ-Documentation for software Qualification
  • Automatic evaluation of validation processes

 

Interface Set SI 1300

  • USB-connector
  • Colored LED signals programming,
    readout and faulty execution
  • Including Antenna AL 111
  • Software Winlog.pro

Interface Set SI 1100

  • USB-connector
  • Colored LED signals programming,
    readout and faulty execution
  • Software Winlog.pro

Video Information​

More Information

Get more information and English manual for this Temperature Data Logger here!