Home » SI Analytics » Piston Burettes and Titrators with Interchangeable Modules » TitroLine® 7000 – Automatic Titrator with Exchangeable Head

TitroLine® 7000 – Automatic Titrator with Exchangeable Head

TitroLine® 7000 - Automatic Titrator with Exchangeable HeadWith its performance spectrum, the automatic titrator TitroLine® 7000 is the ideal starting device for all potentiometric titrations with potential for expansion and automation.

Thanks to the high-resolution and precise pH/mV and “dead-stop” measuring interface, it is possible to determine a wide range of parameters quickly, reliable and accurate.

The easy exchangeable burette heads with a size of 5, 10, 20 and 50 allows a quick change between the different titrants.

TitroLine® 7000 - Automatic Titrator with Exchangeable Head

With its performance spectrum, the automatic titrator TitroLine® 7000 is the ideal starting device for all potentiometric titrations with potential for expansion and automation.

Thanks to the high-resolution and precise pH/mV and “dead-stop” measuring interface, it is possible to determine a wide range of parameters quickly, reliable and accurate.

The easy exchangeable burette heads with a size of 5, 10, 20 and 50 allows a quick change between the different titrants.

Automatic Titrator for exchangeable heads for potentiometry

With its performance spectrum, the TitroLine® 7000 is the ideal starting device for potentiometric titration with potential for expansion and automation. Thanks to the high-resolution and precise pH/ mV and “dead-stop” measuring interface, it is possible to determine a wide range of parameters quickly, reliable and accurate.

The TitroLine® 7000 can be used in all industries such as the chemical, petrochemical, pharmaceutical as well as the food and beverage industry and education. Also well usable for the water and wastewater industry.

The TitroLine® 7000 with has an exceptional high visibility full color graphic display which allows viewing even at extreme angles. The titration curve, but also other information such as ml, pH/mV/µA and temperature are clearly displayed on the display.

The three USB, two RS 232 and Ethernet interfaces makes the TitroLine® 7000 highly communicative. Various USB devices such as printers, barcode readers, keyboards can be connected. Analytical balances, PC and other SI Analytics devices such as the autosampler TW 7200 and other SI Analytics devices can be connected via the RS-232 interfaces. The Ethernet interface allows data to be stored on a directly connected USB stick in PDF and CSV format as well as on shared network directories.

The TitroLine 7000 can be used as a stand-alone instrument but can also be subsequently expanded to a complex system for high sample throughput by adding additional TITRONIC 300 and 500 piston burettes, TitriSoft 3.5/3.5 P software and TW 7200 and TW 7450 sample changers.

The parameters can be customized in each of the up to 50 methods. Through the user/password management, each user can be assigned individual rights. If you need even more methods or want to manage the data on a PC, you can use the PC software TitriSoft 3.5 (TZ 3571) to control the TL 7500 KF. The TitriSoft 3.5P (TZ 3572) comply fully with 21 CFR, Part 11.

Besides the specifications of the instrument series from the general part already mentioned in the introduction and the features of the TITRONIC 500 and TitroLine 5000, the TitroLine 7000 provides more:

As s rule, 10 to 15 user methods are usually sufficient for the most requirements. But sometimes you need a little bit more capacity. The TitroLine 7000 offers storage up to 50 user methods.

Measurement and calibration with the highest accuracy: The wireless recognition automatically recognizes SI Analytics ID electrodes and instantly stores dedicated sensor data eliminating measurement and calibration errors.

TitroLine® 7000 - Automatic Titrator

General Features

  • High visibility, full color display that can be easily viewed from a distance and at extreme angles.
  • Reagent data is securely stored in the intelligent and interchangeable modules
  • Includes up to three USB, on Ethernet and two RS232 ports for expansion and connection of devices
  • Export the results as PDF or CSV, also to networks.

Specific Features for The TitroLine® 7000

  • Automatic wireless recognition of SI Analytics ID electrodes guarantees accurate calibration and measurements.
  • High resolution pH/mV-electrode and temperature inputs for pH, ISE, redox (ORP) or photometric titrations.
  • Perfect for non-aqueous titration such as acid and base numbers in oils (TAN and TBN)
  • Polarizable electrode input for set endpoint titrations („Dead-stop“)
  • Linear (fixed increment) and dynamic equivalence point titration mode and titration to endpoints.
  • pH Stat titrations
  • Single and continuous measuring function
  • Formula editor for individual calculations
  • User management/password
  • Default methods for many different applications such alkalinity, total hardness, total acidity in drinks, chloride, SO2, TAN, TBN, and many others.
  • Titrations with the photometric sensor OptiLine 6
  • Dosing up with up to two connected piston burettes per method
  • Titration with external piston burette

Titrations with The Photometric Sensor OptiLine 6

The TitroLine 7000 allows the connection via USB of the new OptiLine 6 photometric sensor. The TitroLine 7000 uses the digital USB input to set thewavelength and other parameters of the photometric sensor.

With OptiLine 6, e.g., the following applications are possible:

  • All complexometric titrations of metals such as calcium, magnesium (total hardness), zinc, copper, etc.
  • All titrations with color indicator, which are prescribed in the Ph.Eur, USP, and further pharmacopeials. These titrations can now be performed automatically.
  • Turbidity of Total Acid or Bases Number (TAN and TBN) using the color indicator method.
  • Determination of carboxyl end groups in polyethylene terephthalate (PET)

Typical application of water/wastewater and environmental analysis:

  • pH-value, alkalinity (“p+m-value”)
  • Permanganate index
  • COD
  • Volatile fatty acids/ Total anorganic carbon (FOS/TAC)
  • Chloride in waste and drinking water
  • Free and total chlorine in drinking and bathing water
  • Ca/Mg- and total hardness
  • Oxygen according to Wrinkler method

Typical applications of food analysis:

  • Salt content (chloride, sodium chloride)
  • pH-value, total acidity in wine, beverages, and food products such as condiments
  • Formol number in fruit and vegetables juices
  • Ascorbic acid (vitamin C)
  • Calcium in milk and dairy products
  • Reducing sugar in wine and juices
  • Iodine number, peroxide number, free fatty acids and saponification number
  • Determination of free and total sulphurous acid (H2SO3) in wine and must. Further detail is available in the application sample.

Specifications TitroLine®7000

TitroLine®7000
Measuring input analog
pH/mV-input with 24-bit transducer. Electrode socket according to DIN 19 262 or BNC with RFID receiver for SI Analytics ID electrodes
Measuring range pH/accuracy
- 3.0… 18.00 / 0.002 +/- 1 digit
Measuring range mV/accuracy
- 2000…2000/ 0.1 +/- 1 digit
Measuring input µA:
μA-connector for double platinum electrodes, connection: 2 x 4 mm - sockets), polarisation voltage variably adjustable
Measuring input temperature:
Connector for Pt 1000 / NTC 30 KOhm (connection: 2 x 4 mm - sockets)
Measuring range temperature
Pt 1000 - 75…195 °C / NTC 30 KOhm - 40 …125 °C
Interfaces:
3 × USB (2 x USB-A and 1 × USB-B), 2 × RS-232-C and 1 x LAN
Interchangeable burettes
5, 10, 20 ml or 50 ml intelligent interchangeable burette units
Resolution (Steps):
20.000 steps
Dosing accuracy:

according to DIN ISO 8655, part 3:
accuracy: < 0.15 %
precision: < 0.05 - 0.07 % (in dependence of the used burette size)

Display
3.5 inches - 1/4 VGA TFT graphic color display with 320 x 240 pixels
Housing material
Polypropylene
Dimensions
15.3 x 45 x 29.6 cm (W x H x D), height with interchangeable head
Front keyboard
Polyester coated
Material interchangeable burettes
Valve: PTFE/ETFE; Cylinder: borosilikate glass 3.3 (DURAN®) hoses (FEP, blue)
Weight
2.3 kg for basic device, 3.5 kg für complete device with interchangeable head (with empty reagent bottle)
Ambient conditions
Ambient temperature: + 10 ... + 40 °C for operation and storage Humidity according to EN 61 010, Part 1: max. relative humidity 80 % for temperatures up to 31 °C, linear decrease down to 50 % relative humidity at a temperature of 40 °C
Power supply:
100-240 V; 50/60 Hz, power input: 30 VA
CE-sign:

EMC compatibility according to the Council Directive: 2004/108/EG; applied harmonized standards: EN 61326-1:2006
Low-voltage directive according to the Council Directive 2006/95/EG Testing basis EN 61 010, Part 1