Home » SI Analytics » Universal Titrator and Universal Titrator with IDS technology » TitroLine® 7800 – Universal Titrator with IDS-Technology

TitroLine® 7800 – Universal Titrator with IDS-Technology

TitroLine® 7800 – Universal Titrator with IDS-TechnologyThe Titroline® 7800 is automatic Titrator with IDS technology for exchangeable heads for potentiometry and KF.

The Titroline® 7800 enhanced the universal features of the TitroLine® 7750 with an additional IDS measurement socket. Hence the TitroLine® 7800 can perform potentiometric titrations with analog and IDS electrodes up to volumetric KF titrations. The digital (IDS) measurement socket allows the connection of various digital sensors, such as for measuring of conductivity.

TitroLine® 7800 – Universal Titrator with IDS-Technology

The Titroline® 7800 is automatic Titrator with IDS technology for exchangeable heads for potentiometry and KF.

The Titroline® 7800 enhanced the universal features of the TitroLine® 7750 with an additional IDS measurement socket. Hence the TitroLine® 7800 can perform potentiometric titrations with analog and IDS electrodes up to volumetric KF titrations. The digital (IDS) measurement socket allows the connection of various digital sensors, such as for measuring of conductivity.

General features TitroLine® 7800

  • High visibility, full color display that can be easily viewed from a distance and at extreme angles.
  • With new interchangeable modules which all relevant reagent and unit data can be stored
  • Expandable thanks to the 2 x USB-host, 1 x USB-PC, 1 LAN and 2 x RS232 ports. Connectable are 2.g., USB keyboard, USB printer, barcode reader, USB flash drives, balances, PC and further SI Analytics devices such as piston burettes and sample changers.
  • Storage of results using via USB port (PDF – and CSV-format) including method transfer.
  • With standars methods for potentiometric and KF titration
  • Second digital measuring port for Intelligent Digital Sensors (IDS)
  • Export the results as PDF or CSV, also to networks.
  • Reagent data is securely stored in the intelligent and interchangeable modules

Specific features for the TitroLine® 7800

  • Automatic wireless recognition of SI Analytics ID electrodes guarantees accurate calibration and measurements.
  • High resolution pH/mV-electrode and temperature inputs for pH, ISE, redox (ORP) or photometric titrations.
  • Second digital measuring socket for intelligent digital pH-, conductivity, ORP sensors (IDS)
  • Perfect for non-aqueous titration such as acid and base numbers in oils (TAN and TBN)
  • Polarizable electrode input for set endpoint titrations („Dead-stop“ + KF)
  • Linear (fixed increment) and dynamic equivalence point titration mode and titration to endpoints
  • pH Stat titrations
  • volumetric KF titrations
  • Single and continuous measuring function
  • Formula editor for individual calculations
  • User management/password

Latest features :

  • Titrations with the new photometric sensor OptiLine 6
  • Dosing with up to two connected piston burettes per method
  • Titration with external piston burette

Ideal for measurements and titration tasks with pH and Conductivity

The TitroLine® 7800 is ideally suited for use in water analysis. A typical example is the measuring of the pH and conductivity. Subsequently, as a rule the Alkalinity or Carbonate/Hydrogen carbonate hardness is determined.

Conductivity and temperature are measured immediately after the two measuring electrodes are immersed in the sample. This will take a few seconds. Then the pH value is determined by drift control. This can take more than a minute for low-ion water samples. There is no mutual influence on the pH and the LF value due to the use of the digital conductivity electrode.

The acid capacity KS8.2 and KS4.3 are then titrated with hydrochloric acid 0.02–0.1 mol / l. The titration is carried out to a pH of 4.3 (4.5) and the consumption is determined at pH 8.2 and 4.3 (or 4.5).

TitroLine® 7800 display

This application is very easy to automate with a sample changer. If many samples have to be measured per day, the TW 7200 and TW 7450 are used. It is also possible to calibrate the pH electrode in the sample changer at startup.

Specifications TitroLine® 7800

Spesifications
Measuring input 1 (analog)
pH/mV-input with 24-bit transducer. Electrode socket according to DIN 19 262 or BNC with RFID receiver for SI Analytics ID electrodes
Measuring range pH/accuracy
- 3.0… 18.00 / 0.002 +/- 1 digit
Measuring range mV/accuracy
- 2000…2000/ 0.1 +/- 1 digit
Measuring input µA:
μA-connector for double platinum electrodes, connection: 2 x 4 mm - sockets), polarisation voltage variably adjustable
Measuring input temperature:
Connector for Pt 1000 / NTC 30 KOhm (connection: 2 x 4 mm - sockets)
Measuring input: (digital), IDS
Digital input for teh connection of IDS®-sensors (pH, mV, conductivity)/ accuracy depends on teh connected sensor
pH
0.000…14.000+/- 0.004
mV
+/- 1200 +/- 0.2
Temperature °C
- 5.0…105 +/- 0.2
Conductivity
0.00…2000 mS/cm +/- 0,5% from measurement value
Interfaces:
3 × USB (2 x USB-A and 1 × USB-B), 2 × RS-232-C and 1 x LAN
Interchangeable burettes
5, 10, 20 ml or 50 ml intelligent interchangeable burette head
Resolution (Steps):
20.000 steps
Dosing accuracy:

according to DIN ISO 8655, part 3:
accuracy: < 0.15 %
precision: < 0.05 - 0.07 % (in dependence of the used burette size)

Display
3.5 inches - 1/4 VGA TFT graphic color display with 320 x 240 pixels
Housing material
Polypropylene
Dimensions
15.3 x 45 x 29.6 cm (W x H x D), height with interchangeable head
Front keyboard
Polyester coated
Material interchangeable burettes

Valve: PTFE/ETFE;
Cylinder: borosilikate glass 3.3 (DURAN®)
hoses (FEP, blue)

Weight
2.3 kg for basic device, 3.5 kg für complete device with interchangeable head (with empty reagent bottle)
Ambient conditions
Ambient temperature: + 10 ... + 40 °C for operation and storage Humidity according to EN 61 010, Part 1: max. relative humidity 80 % for temperatures up to 31 °C, linear decrease down to 50 % relative humidity at a temperature of 40 °C
Power supply:
100-240 V; 50/60 Hz, power input: 30 VA
CE-sign:

EMC compatibility according to the Council Directive: 2004/108/EG; applied harmonized standards: EN 61326-1:2006
Low-voltage directive according to the Council Directive 2006/95/EG Testing basis EN 61 010, Part 1

Several types of TitroLine®7800 – Universal Titrator with IDS-Technology:

1. TitroLine®7800 Basic Unit

TitroLine®7800 Basic Unit

Scope of delivery:
Basic unit without magnetic stirrer and without exchangeable head, with keyboard, hand controller, stand rod and titration clamp Z 305, power supply 100-240 V.

2. TitroLine® 7800 Basic Unit with Magnetic Stirrer

TitroLine® 7800 Basic Unit with Magnetic Stirrer

Scope of delivery:
Basic unit with magnetic stirrer, without exchangeable head, with keyboard, hand controller, stand rod and titration clamp Z 305, power supply 100-240 V.

3. TitroLine® 7800 Basic Unit with Magnetic Stirrer and Software TitriSoft 3.5

TitroLine® 7800 Basic Unit with Magnetic Stirrer and Software TitriSoft 3.5

Scope of delivery:
Software on USB-stick, RS232-connection cable TZ 3097, USB-RS-converter TZ 3080 and USB cable. TitroLine® 7800 basic unit with magnetic stirrer, without exchangeable head, with keyboard, hand controller, stand rod and titration clamp Z 305, power supply 100-240 V.

Ordering Information TitroLine® 7800

Type No. Order No. Description
TL 7800
285220980
TitroLine® 7800 basic unit with two measuring inputs, one analogue and one digital (IDS) measuring input
TL 7800-M1
285220990
TitroLine® 7800 basic unit with two measuring inputs, one analogue and one digital (IDS) measuring input, with magnetic stirrer TM 235
TL 7800-TitriSoft
285221030
Basic unit with two measuring inputs, one analogue and one digital (IDS) measuring input, with magnetic stirrer TM 235 and TitriSoft 3.5

Ordering Information Accessories for TitroLine® 7800

Type No. Order No. Description
WA 05
285220300
5 ml exchangeable unit with integrated chip for reagent data, with brown glass bottle for titrant, GL 45 and S 40-bottle adapter, tubes, drip tube and titration tip
WA 10
285220310
10 ml exchangeable unit with integrated chip for reagent data, with brown glass bottle for titrant, GL 45 and S 40-bottle adapter, tubes, drip tube and titration tip
WA 20
285220320
20 ml exchangeable unit with integrated chip for reagent data, with brown glass bottle for titrant, GL 45 and S 40-bottle adapter, tubes, drip tube and titration tip
WA 50
285220350
50 ml exchangeable unit with integrated chip for reagent data, with brown glass bottle for titrant, GL 45 and S 40-bottle adapter, tubes, drip tube and titration tip
TM 235, 115-230 V
285220400
Magnetic stirrer for vessels up to 500 ml, agitator speed infinitely adjustable from 500 - 2000 rpm, for the connection to TitroLine® 6000/7000 and TITRONIC® 500
TM 235 KF, 115-230 V
285220900
Titriation stand with pump; Scope of delivery: Basic unit with 1 l DURAN ®-reagent bottle TZ 1791, 1 l DURAN®-waste bottle TZ 1792, moisture bottle, tubes and screw threads, power supply TZ 1855 (110 to 240 V)
TZ 1052
285214721
KF-drying stove, 230 V
TZ 1055
285215183
KF-drying stove, 115 V
TZ 1060
285218115
Accessories set for KF drying stove TZ 1052/TZ1055
TZ 1065
285201973
Flowmeter with valve and hose connectors for gas volumes (air, nitrogen) from 50 - 500 ml/min
KF 1100
285102030
Micro double platinum electrode for Karl Fischer titrations, with fixed cable, double platinum pin and tapper NS 7.5 for TZ 1770 and TZ 1772
TZ 1748
285216560
Stand rod stainless steel Ø 10 mm
TZ 1770
285216677
Karl Fischer titration vessel. DURAN® glass vessel TZ 1775 (approx. 30...150 ml), removable head made of polypropylene/PTFE, 1 drilling NS 19, NS 14,5, NS 7,5 and 3 drillings with screw threads, titration tip, moisture trap and weighing funnel
TZ 1789
285221120
Starter kit KF consisting of molecular sieve, needles with syringes and glass wool
TZ 3863
285220480
USB-thermo printer, 112 mm for TitroLine® 6000/7000/7500 KF/7500 KF trace/7750 and TITRONIC® 500
TZ 3864
285220710
Thermal paper for TZ 3863 with very high durability (5 rolls)

More Information

Get more information and English manual for this  Automatic Titrator here!

Share this information :

Similar Posts