Home » SI Analytics » Sample Changer for Titration » TW 7200 – Rotary Sample Changer for Piston Burettes and Automatic Titrators

TW 7200 – Rotary Sample Changer for Piston Burettes and Automatic Titrators

TW 7200 - Rotary Sample Changer for Piston Burettes and Automatic TitratorsThe number of samples to be processed is growing constantly while at the same time the demands on reliability are increasing in accordance with GLP and ISO standards. The SI Analytics Sample Changer (TW 7200) helps you meet these increased requirements and free up highly qualified employees from routine work.

Depending on your application, the Sample Changer from SI Analytics can be customised with sample trays of varying size as well as a rinsing pump. Sample trays are available with 12, 16, 18, 24, and 48 positions for accommodating sample vessels with a diameter of 28-82mm.

TW 7200 - Rotary Sample Changer for Piston Burettes and Automatic Titrators

The number of samples to be processed is growing constantly while at the same time the demands on reliability are increasing in accordance with GLP and ISO standards. The SI Analytics Sample Changer (TW 7200) helps you meet these increased requirements and free up highly qualified employees from routine work.

Depending on your application, the Sample Changer from SI Analytics can be customised with sample trays of varying size as well as a rinsing pump. Sample trays are available with 12, 16, 18, 24, and 48 positions for accommodating sample vessels with a diameter of 28-82mm.

The Sample Changer (TW 7200) is controlled by your PC (not supplied) and SI Analytics’ TitriSoft software (sold separately). The TitriSoft titration software is the optimum solution for your titration tasks. The software supports your daily work procedures during sample preparation, titration and evaluation of results.

Exchangeable sample trays for more flexibility

TW 7200 - Exchangeable sample trays

With sample trays or racks and titration head fittings for a variety of beaker and titrator vessels, you get the flexibility your lab needs.

The sample trays and titrator heads are very quick and simple to change. You can conveniently set the respective tray size in the TitriSoft software’s worklist without any need for configuration of the sample changer itself.

Rinsing of electrode and titration tip

Rinsing of electrode and titration tipTo ensure the accuracy of the results, electrodes, and titration tips are rinsed after each titration. This can be done by immersing the electrodes and titration tips in a rinsing solution. How many rinsing positions are to be used and how long rinsing is to be carried out is defined in the worklist.

A direct and fast rinsing of the electrodes and titration tips can be carried out by connecting the MP 25 rinsing pump. This involves rinsing directly after the titration either into the titrated sample (TW 7200-16-MP, TW 7450-42-MP) or into a special rinsing vessel at position one (TW 745048-MP and TW 7450-72-MP).

Finally, a waiting position can be approached to immerse pH electrodes in a KCl solution and prevent them from drying out.

By using an optional second pump, the titrated solution as well as the rinsing solution can be aspirated.

Photo on the left-hand side: The connection of a rinsing nozzle in the TZ 3974 titration head now also enables rinsing on the first position into a special rinsing vessel. The rinsing liquid drains from the rinsing vessel into a waste vessel by gravity.

Stirring “from above” or “from below”

Stirring “from above” or “from below”Two magnetic stirrers allowing the samples to be stirred “from below” are installed in the TW 7200 as a standard.

Alternatively, you can use a rod stirrer which allows stirring “from above”.

Automatic COD titration

Automatic COD titrationFor the direct titration of the chemical oxygen demand (COD) in the digestion vessels, a special sample tray with twenty-four positions and a matching titration head are available for the TW 7200.

Titration heads and sample trays

Due to the built-in head motor of the TW 7200, double-row sample trays can be used in place of single-row versions simply by switching them over. No need for any special adaptations or modifications. Examples, from left to right:
TZ 4016, single-row,16 sample positions
TZ 4025, double-row, 25 sample positions
TZ 4038, double-row, 38 sample positions
TZ 4050, double-row, 48 sample positions

Titration heads and sample trays
Titration head TZ 1464

Titration head TZ 1464

Suitable for the TZ 4018 and TZ 401 sample trays with 18 and 28 positions for 100 ml beakers. Four openings are available for electrodes, titration tips and the rod stirrer.

Titration head TZ 1467 with splash shield and rinsing nozzle

Suitable for the TZ 4012, TZ 4016 and TZ 4025 sample trays from 12 to 25 positions for 150 ml to 400 ml beakers.

Six openings are then still available for electrodes, titrationtips and the rod stirrer.

Titration head TZ 1463

Titration head TZ 1463

Suitable for TZ 4012, TZ 4016, TZ 4025 and TZ 4053 sample trays from 12 to 25 positions for 150 ml to 600 ml beakers.

The titration head is also used for the TZ 4030, TZ 4050 and TZ 4058 sample trays for special dosing tasks such as sample preparation. A total of seven openings are available for electrodes, titration tips and the rod stirrer.

Titration head TZ 1469

New: Titration head TZ 1469 for 24 and 38 position sample trays

The TZ 1469 micro-titration head now also allows the simultaneous use of a conductivity and a pH electrode (micro version such as SCPpHT-MIC-AMF-3MDIN-N, 285101335) and rod stirrer.

Without a rod stirrer, a standard pH electrode with 12 mm diameter can also be used. Titration tips can be accommodated in the head too.

 

Key Features of TW 7200

  • Titration heads and sample trays can be easily changed
  • Interchangeable Sample trays (12 – 48 positions)
  • Stirring from below is possible with the two built-in magnetic stirrers or from above with an optional rod stirrer (propeller stirrer)
  • The size of the sample tray is set in TitriSoft
  • Built-in horizontal titration head motor for positioning in another sample row
  • Connection of two pumps (diaphragm and peristaltic pumps) for rinsing of the electrodes and titration tips and for the suction of the sample
  • pH electrode calibration can be done on the sample changer.

Specifications of TW 7200

Specifications
Interfaces:
2 × RS-232-C, 1 x I/O, 2 x pumps, 1 x stirrer, 1 USB-A (Update only), 1 USB-Mini-B (PC), 1 x Ethernet
Housing Material:

Housing made of two-component- coated ALU, steel sheet, and epoxy resin
Sample tray: aluminium powder coated

Dimensions:

Basic unit: 143 x 620 x 505 mm (W x H x D)
Sample tray: 450 mm

Weight:

10,3 Kg Examples with sample trays
Sample tray with 16 beaker glasses 150 ml: approx.2.6 kg
Sample tray with 24 beaker glasses 50 ml: approx. 2.4 kg
Sample tray with 24 reaction vessels: approx.6.3 kg

Ambient conditions:
Ambient temperature: + 10 ... + 40 °C for operation and storage Humidity according to EN 61 010, Part 1: max. relative humidity 80 % for temperatures up to 31 °C, linear decrease down to 50 % relative humidity at a temperature of 40 °C
Power supply:
115 - 240 V~, 50/60 Hz, 30 VA
Magnetic stirrer:
2 fixed magnetic stirrers
Horizontal motor:
Horizontal motor for driving a second sample beaker row
Sample trays:
From 12 - 48 positions

Ordering Information TW 7200 Sample Changers (Basic Unit)

Type No. Order No. Description
TW 7200
285228000
Basic unit TW 7200 with two integrated magnetic stirrers, connection cable for rod stirrer, USB connection cable TZ 3887, power supply 100–240 V
TW 7200-16
285228010
Basic unit TW 7200 with sample rack TZ 4016 for 16 samples, without beakers, incl. titration head TZ 1463 and power supply 100–240 V
TW 7200-18
285228020
Basic unit TW 7200 with sample rack TZ 4018 for 18 samples, without beakers, incl. titration head TZ 1464 and power supply 100–240 V
TW 7200-24
285228030
Basic unit TW 7200 with sample rack TZ 4024 for 24 samples, without beakers, incl. titration head TZ 1469, power supply 100–240 V
TW 7200-COD
285228040
Basic unit TW 7200 with sample rack TZ 4040 for 24 CSB-samples according to DIN 38 409, without vessels, incl. Titration head TZ 1461, redox electrode Pt 5901, rod stirrer TZ 1846, titration tip TZ 1648, power supply 100–240 V
TW 7200-16-MP
285228050
Basic unit TW 7200 with sample rack TZ 4016 for 16 samples, without beakers, incl. titration head TZ 1467, rinsing pump MP 25, power supply 100–240 V
TW 7200-25
285228200
Basic unit TW 7200 with sample rack TZ 4025 for 25 samples, without beakers, incl. titration head TZ 1463 and power supply 100–240 V
TW 7200-25-MP
285228210
Basic unit TW 7200 with sample rack TZ 4025 for 25 samples, without beakers, incl. titration head TZ 1467, rinsing pump MP 25, power supply 100–240

Ordering Information TW 7200 Sample Changers (Sets)

Type No. Order No. Description
TL 7000 TW 7200-16 Set
285228060
Complete sample change set consists of TL 7000-M2-20, sampler changer TW 7200-24 and 3 x beaker sets TZ 1783, titration tip TZ 1646 and titration tube TZ 3415; incl. Software TitriSoft
TL 7000 TW 7200-24 Set
285228070
Complete sample change set consists of TL 7000-M2-20, sampler changer TW 7200-24 and 3 x beaker sets TZ 1783, titration tip TZ 1646 and titration tube TZ 3415; incl. software TitriSoft

Ordering Information TW 7200 Trays/Racks and Titration Heads

Type No. Order No. Description
TZ 4012
285228080
Sample tray for TW 7200, for 12 sample vessels, incl. 20 beakers, 250 ml, low form
TZ 4016
285228090
Sample tray for TW 7200 for 16 sample vessels without beakers. Suitable beakers are 150 ml TZ 1784, TZ 1788 or 250 ml TZ 1787, TZ 1780.
TZ 4018
285228100
Sample tray for TW 7200, for 18 sample vessels without beakers. Suitable beakers are TZ 1765 (100 ml tall form without spout)
TZ 4024
285228110
Sample tray for TW 7200, for 24 sample vessels without beakers. Suitable beakers are 50 ml TZ 1783 / 75 ml TZ 1786
TZ 4025
285228120
Sample tray for TW 7200, double row for 25 sample vessels, without beakers. Suitable beakers are 150 ml TZ 1784, TZ 1788 or 250 ml TZ 1787, TZ 1780
TZ 4028
285228130
Sample tray for TW 7200, double row for 28 sample vessels, without beakers. Suitable beakers are TZ 1765 (100 ml tall form without spout)
TZ 4030
285228140
Sample tray for TW 7200, for 24 sample vessels, without vessel. Suitable for 40 ml sample vials with ND 24 VZ 7088
TZ 4038
285228150
Sample tray for TW 7200, double row for 38 sample vessels, without beakers. Suitable beakers are 50 ml TZ 1783 / 75 ml TZ 1786
TZ 4040
285228160
Sample tray for TW 7200, for 24 COD vessels according to DIN 38 409, without vessels
TZ 4050
285228170
Sample tray for TW 7200, double row for 48 sample vessels, without vessels. Suitable for 40 ml sample vials with ND 24 VZ 7088
TZ 4053
285228180
Sample tray for TW 7200, for 12 sample vessels, incl. 20 beakers 600 ml, tall form
TZ 4058
285228190
Sample tray for TW 7200, for 16 sample vessels, without bottles. Suitable for 100 ml laboratory bottles VZ 7081
TZ 1461
285213622
Titration head for COD sample tray for TW 7200
TZ 1462
285213639
Titration head for KF titration for sample tray TZ 4024 or TZ 4038 for TW 7200
TZ 1463
285213647
Titration head for sample tray TZ 4012 and sample tray TZ 4016/TZ 4025, as well as TZ 4030, TZ 4050, TZ 4053 and TZ 4058 with 7 openings NS 14
TZ 1464
285213654
Titration head for sample tray TZ 4018/TZ4028 with four openings with different diameters
TZ 1467
285213671
Titration head for sample tray TZ 4012/TZ 4016/TZ 4025 with 7 openings NS 14 incl. splash shield and rinsing tube
TZ 1469
285213884
Titration head for sample tray TZ 4024 and TZ 4038 with 5 x openings (1 x NS 14, 1 x 15.3 mm and 2 x NS 7 + 1 x 3 mm for FEP-tubes). With adapter TZ 1526 for 12 mm standard electrodes

Ordering Information: Other Accessories

Type No. Order No. Description
TZ 1465
285213980
Cap made out of plastic, with opening for titration vessel TZ 1786, 12 pcs.
TZ 1466
285213990
Aluminium foil for titration vessel TZ 1786, 500 pcs.
TZ 1785
1064589
Glass titration beaker, 250 ml low form (10 pcs.) for TZ 1452/TZ 4012
TZ 1783
1064720
Glass titration beaker, 50 ml tall form (10 pcs.) for TZ 1454/TZ 4024/TZ 4038 and TZ 3972
TZ 1787
285201994
Glass titration beaker, 250 ml tall form (10 pcs.) for TZ 1459/TZ 4016/TZ4025 and TZ 3942
TZ 1788
285202008
Glass titration beaker “super duty", 150 ml low form (10 pcs. for TZ 1459/TZ 4016/TZ4025 and TZ 3942
TZ 1765
285202030
Glass titration beaker, 100 ml tall form (10 pcs.) without spout
TZ 1784
285216747
Glass titration beaker, 150 ml low form (10 pcs.) for TZ 1459/TZ 4016/TZ4025 and TZ 3942
TZ 1786
285216756
Beaker made out of glass for max. 75 ml; diameter 40 mm, height 110 mm (10 pcs) for TZ 1454/TZ 4024/ TZ 4038 and TZ 3972
TZ 1780
285226140
Glass titration beaker “super duty", 250 ml tall form (10 pcs. For TZ 1459/TZ 4016/TZ4025 and TZ 3942
TZ 1766
285226160
Glass titration beaker, 600 ml tall form (10 pcs.) without spout
TZ 1844
285213199
Rod stirrr mid-size model (120 mm) with NS 14.5
TZ 1846
285215134
Rod stirrer long model (200 mm) with NS 14.5 for COD reaction vessels according to DIN 38 409 section 41 for sample changer TW 7200
TZ 1847
285215175
Rod stirrer short model (103 mm) with NS 14.5
TZ 1863
285216530
Propeller blade three-fold made of PTFE

More Information

Get more information and English manual for this  Sample Changer for Piston Burettes and Automatic Titrators here!